Borst Engineering & Construction LLC
Calculator Instructions

Return to Calculator Tab

Steady State Room Temperature Analysis Calculator - Borst Engineering & Construction LLC
Exposed Temp of Room Building Assembly 1 (Deg F)
Exposed Temp of Room Building Assembly 2 (Deg F)
Exposed Temp of Room Building Assembly 3 (Deg F)
Exposed Temp of Room Building Assembly 4 (Deg F)
Exposed Temp of Room Building Assembly 5 (Deg F)
Exposed Temp of Room Building Assembly 6 (Deg F)
Exposed Temp of Room Building Assembly 7 (Deg F)
Exposed Temp of Room Building Assembly 8 (Deg F)
Exposed Temp of Room Building Assembly 9 (Deg F)
Exposed Temp of Room Building Assembly 10 (Deg F)
Outdoor Air Infiltration Temp (Deg F)
Indoor Air Infiltration Temp (Deg F)
Area of Room Building Assembly 1 (SF)
Area of Room Building Assembly 2 (SF)
Area of Room Building Assembly 3 (SF)
Area of Room Building Assembly 4 (SF)
Area of Room Building Assembly 5 (SF)
Area of Room Building Assembly 6 (SF)
Area of Room Building Assembly 7 (SF)
Area of Room Building Assembly 8 (SF)
Area of Room Building Assembly 9 (SF)
Area of Room Building Assembly 10 (SF)
R-Value of Room Building Assembly 1 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 2 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 3 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 4 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 5 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 6 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 7 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 8 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 9 (Deg F-H-SF/BTU)
R-Value of Room Building Assembly 10 (Deg F-H-SF/BTU)
Volume of Room (CF or 0 for CFM)
Outdoor Air Infiltration Rate of Room (ACH or CFM, 0.5 ACH typical for new construction)
Indoor Air Infiltration Rate of Room (ACH or CFM)
Steady State Room Temp (Deg F)
Heat Gain/Loss from Room Building Assembly 1 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 2 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 3 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 4 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 5 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 6 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 7 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 8 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 9 (BTU/Hour)
Heat Gain/Loss from Room Building Assembly 10 (BTU/Hour)
Outdoor Air Infiltration Rate of Room (CFM)
Heat Gain/Loss from Outdoor Air Infiltration (BTU/Hour)
Indoor Air Infiltration Rate of Room (CFM)
Heat Gain/Loss from Indoor Air Infiltration (BTU/Hour)
Borst Engineering & Construction LLC

Terms of Use